Mecsens Asia Co., Ltd.

Follow Us : Google Plus Facebook

Inert Atmosphere Glove Box


Inert Atmosphere Glove Box

We stand tall as the prestigious Manufacturer and Supplier of precision engineered Inert Atmosphere Glove Box from Taiwan. Our team of experts fabricates the Inert Atmosphere Glove Boxes using high-quality basic material and the latest technology. High on counts of quality, efficiency and durability, these Boxes are extensively demanded. For bulk order of Inert Atmosphere Glove Boxes, contact us. We promise timely delivery of all the orders.

 

Characteristics :

Control : Siemen’s PLC Controller & Human Machine Interface Central Controlled
Handing : With Chinese, English, Russia Langue Interface. With 6" Color Touch Screen.

Features :

  • H20 <1 PPM
  • 02 < 1PPM
  • Cleaness
  • Isolate
  • Control : Siemen’sPLC Controller & Human Machine Interface Central Controlled
  • Handing : With Chinese, English, Russia Langue Interface. With 6” Color Touch Screen.
  • Glove Box Pressure Automatic Control & 1 Foot Pedalfor Glove Box Pressure Adjustment
  • Electrical Connection : 220V ï¼ï¿½ACï¼ï¿½50/60Hz.
  • Gas Purification System : Removal of H2O and O2
  • Process : Gas Circulation  Closed Loop  Gas Recirculation
  • Working Gas : Inert Gas Nitrogen . Argon or Helium
  • Attainable Purity ï¼ï¿½Inside Glove Box : H2O<1ppmï¼ï¿½vï¼ï¿½,O2<1ppmï¼ï¿½vï¼ï¿½
  • Purifier : Single Purifier Column, Material Stainless Steel SUS 304, Heater Integrated:1.5kw
  • Regeneration : The Purifier Unit is Regenerable
  • Procedure : Automatic Regeneration Program And Manual Control ï¼ï¿½HMI & PLC Controlledï¼ï¿½
  • Regeneration Gas : N2/H2 mixture ï¼ï¿½H2 10-15%ï¼ï¿½ or Ar/H2mixtureï¼ï¿½H2: 10-15%ï¼ï¿½
  • Cooling : Water Cooling 2-3 1/min
  • Circulation Unit :Integrated Blower . Flow rate : 90m3/h atΔ P=60 mbar
  •                ï¼ï¿½ΔP : Pressure Difference Between Blower And Glove Box Insideï¼ï¿½
  • Vacuum Pump : Edward RV-12 Vane-Type Oil-Rotary Pump Incl. Oil Mist Filter Oil Recirculation And Automatic Gas Ballast Control , Capacity 12m3/h.Dual Stage. Ultimate Vacuum<0.1mbar
  • System Valves : Main Valves ï¼ï¿½For Circulation ï¼ï¿½ : Electro-pneumatic VALVES. Type: KF-40
  • Control Valves : Magnetic Valves 3/8” , PLC controlled
  • System Piping : Main Piping Copper Pipe or Stainless Steel SUS304 Pipe. Type KF-40 flange system
  • Side Piping : Copper Pipe or Stainless Steel Pipe
  • Glove Box Material : Stainless Steel SUS304. Thickness: 3 mm
  • Inside Surface : Brushed Finish Surface , Outside Surface : Enameled RAL6029
  • Feed throughs : 3 spare KF-40
  • Hepa Dust Filter : 2 Pieces ï¼ï¿½1 at gas inlet, 1at gas outletï¼ï¿½ ;
  •  Shelves : 2 Pieces. Material sus304
  • Box Window ï¼ï¿½At The Front of The Glove Box ï¼ï¿½ : 1 Piece Material  thickness 12mm double laminated tempered glass or pc glass
  • Glove Ports ï¼ï¿½ In Front Box Window ï¼ï¿½ : Material : PPS
  • Size : 200mm diameter , O-ring sealed
  • Gloves ï¼ï¿½In Front Box Window, Attached to Glove Ports ï¼ï¿½ :  2 Pieces ,Dia.200mm Length 800mm Material : Butyl, Thickness;0.4mm North
  • Box Light : 1 Set Fluorescent Lamp ,Front Mounted
  • Leak Rate ï¼ï¿½ For Glove Box ï¼ï¿½ : <0.05Vo1%/h
  • Antechamber : Circular Type Antechamber , 385mm Dia. Length 588mmï¼ï¿½Inside Dimensionsï¼ï¿½
  • Material Stainless Steel SUS 304 Thickness 2mm , Siding Tray : Stainless Steel SUS 304
  • Inside Surface Brushed Finish, Outside Surface Enameled .
  • Doors : Material Aluminum, Anodized, Thickness 10mm , Door lock Spindle-Lock, Lilfing Mechanism
  • Tool Antechamber :DN150X350mm
  • Pressure sensor : one sensor range :-2500-2500Pa for Display & control system pressure
  • Valves : Hand or Automatic Valves ï¼ï¿½ KF-40 /25 Vacuum Line/KF-10 refill lineï¼ï¿½
  • Vacuum/ Refill : Manual Operation via Hand Valves or PLC
  • Moisture sensor : Range 0-1000 ppm
  • O2 Sensor : Range 0-1000ppm
  • Organic Solvent trap : Volume 21L install in outside

 

  • Options :
    • Refrigerator : -40â�� 35L
    • Microscope
    • Heating airlock :0-250â��
    • High Temperature Furnace or Hot plate
    • Static Remover
    • UV Lamp Sterilization
    • Spin coater
    • Cold trap
    • Dust Laminar flow device
    • Sealing device
    • Incubator
    • Welding Sealing Device


Labstar Series Glove Box

Model Remarks Box Size The device total size
GS800S One side 2 gloves, single purification column length 1200ï¼bottom width 800ï¼top width 700ï¼high 930 length 1915ï¼width 830ï¼high1830
GS800D One side 2 gloves, double purification columns
DG1000S Double sides 4 gloves,single purification column length 1200ï¼bottom width 1000ï¼top width 800ï¼high 930 length 1915ï¼width 1060ï¼
high 1830
DG1000D Double sides 4 gloves,double purification columns length 1200ï¼bottom width 1000ï¼top width 800ï¼high 930 length 1915ï¼width 1060ï¼
high 1830
DG1200S Double sides 4 gloves,single purification column length 1200ï¼bottom width 1200ï¼top width 1000ï¼high 930 length 1915ï¼width 1260ï¼
high 1830
DG1200D Double sides 4 gloves,double purification columns length 1200ï¼bottom width 1200ï¼top width 1000ï¼high 930 length 1915ï¼width 1260ï¼
high 1830